When to run a blank using ICP-MS












2












$begingroup$


I am currently writing a paper for my Advanced Analytical Chemistry course, and the topic I am writing on is the analysis of Arsenic in drinking water. The EPA's literature describes how to perform this method but does not describe how many samples should be taken or when and where blanks should be used. The three blanks required for analysis are the rinse blank, calibration blank, and the laboratory reagent blank. My question is, if we assume we are analyzing twenty water samples using ICP-MS, when should each type of blank be run?










share|improve this question







New contributor




Dillon Stetler is a new contributor to this site. Take care in asking for clarification, commenting, and answering.
Check out our Code of Conduct.







$endgroup$

















    2












    $begingroup$


    I am currently writing a paper for my Advanced Analytical Chemistry course, and the topic I am writing on is the analysis of Arsenic in drinking water. The EPA's literature describes how to perform this method but does not describe how many samples should be taken or when and where blanks should be used. The three blanks required for analysis are the rinse blank, calibration blank, and the laboratory reagent blank. My question is, if we assume we are analyzing twenty water samples using ICP-MS, when should each type of blank be run?










    share|improve this question







    New contributor




    Dillon Stetler is a new contributor to this site. Take care in asking for clarification, commenting, and answering.
    Check out our Code of Conduct.







    $endgroup$















      2












      2








      2





      $begingroup$


      I am currently writing a paper for my Advanced Analytical Chemistry course, and the topic I am writing on is the analysis of Arsenic in drinking water. The EPA's literature describes how to perform this method but does not describe how many samples should be taken or when and where blanks should be used. The three blanks required for analysis are the rinse blank, calibration blank, and the laboratory reagent blank. My question is, if we assume we are analyzing twenty water samples using ICP-MS, when should each type of blank be run?










      share|improve this question







      New contributor




      Dillon Stetler is a new contributor to this site. Take care in asking for clarification, commenting, and answering.
      Check out our Code of Conduct.







      $endgroup$




      I am currently writing a paper for my Advanced Analytical Chemistry course, and the topic I am writing on is the analysis of Arsenic in drinking water. The EPA's literature describes how to perform this method but does not describe how many samples should be taken or when and where blanks should be used. The three blanks required for analysis are the rinse blank, calibration blank, and the laboratory reagent blank. My question is, if we assume we are analyzing twenty water samples using ICP-MS, when should each type of blank be run?







      analytical-chemistry






      share|improve this question







      New contributor




      Dillon Stetler is a new contributor to this site. Take care in asking for clarification, commenting, and answering.
      Check out our Code of Conduct.











      share|improve this question







      New contributor




      Dillon Stetler is a new contributor to this site. Take care in asking for clarification, commenting, and answering.
      Check out our Code of Conduct.









      share|improve this question




      share|improve this question






      New contributor




      Dillon Stetler is a new contributor to this site. Take care in asking for clarification, commenting, and answering.
      Check out our Code of Conduct.









      asked 4 hours ago









      Dillon StetlerDillon Stetler

      111




      111




      New contributor




      Dillon Stetler is a new contributor to this site. Take care in asking for clarification, commenting, and answering.
      Check out our Code of Conduct.





      New contributor





      Dillon Stetler is a new contributor to this site. Take care in asking for clarification, commenting, and answering.
      Check out our Code of Conduct.






      Dillon Stetler is a new contributor to this site. Take care in asking for clarification, commenting, and answering.
      Check out our Code of Conduct.






















          1 Answer
          1






          active

          oldest

          votes


















          2












          $begingroup$

          This terminology is specific to EPA and it is not universal, because there are so many legal issues associated with any environmental analysis. They have to be extremely careful at each and every step (it may cost someone millions because of a wrong analytical result). Hence the reason for various "blanks." The language of those methods is official and the steps are highly detailed. Hence these robust methods can be defended legally using the terminologies used in the methods.



          While preparing a calibration curve by ICP or any other spectrochemical technique, there can be only one blank, which sets the baseline reading. One would run this blank and 5-6 standards. So which blank is this? By EPA nomenclature, this is the calibration blank, which is defined by them as "Calibration Blank – A blank solution containing all of the reagents in the same concentration as those used in the analytical sample preparation. This blank is not subject to the preparation method." Pretty much standard definition.



          So what are the other plenty of blank solutions doing? They are used for quality control after the calibration to check the accuracy of the instrument, method, operator etc. One can test them right after performing the calibration process. See how specific the directions are:



          a) Laboratory Reagent Blank (LRB) – An aliquot of ASTM Type I water that is treated exactly as a sample including exposure to all labware, equipment, solvents, reagents and internal standards that are used with other samples. The LRB is used to determine if method analytes or other interferences are present in the laboratory environment, the reagents or apparatus.



          b) The rinse blank, as the name indicates for rinsing the lines. You should discuss how complex the sample introduction system is in ICPs. >90% sample is wasted and a small fraction goes to the plasma.



          EPA defines it as well. The rinse blank should flush the system between solution changes for blanks, standards, and samples. Allow sufficient rinse time (~ 1 min) to remove traces of the previous sample. Solutions should aspirate for at least 30 seconds prior to the acquisition of data to establish equilibrium



          Reference: this detailed report with terminologies



          (ICP-MS) with - EPA: https://www3.epa.gov/ttnamti1/files/ambient/pb/EQL-0512-202.pdf






          share|improve this answer









          $endgroup$














            Your Answer








            StackExchange.ready(function() {
            var channelOptions = {
            tags: "".split(" "),
            id: "431"
            };
            initTagRenderer("".split(" "), "".split(" "), channelOptions);

            StackExchange.using("externalEditor", function() {
            // Have to fire editor after snippets, if snippets enabled
            if (StackExchange.settings.snippets.snippetsEnabled) {
            StackExchange.using("snippets", function() {
            createEditor();
            });
            }
            else {
            createEditor();
            }
            });

            function createEditor() {
            StackExchange.prepareEditor({
            heartbeatType: 'answer',
            autoActivateHeartbeat: false,
            convertImagesToLinks: false,
            noModals: true,
            showLowRepImageUploadWarning: true,
            reputationToPostImages: null,
            bindNavPrevention: true,
            postfix: "",
            imageUploader: {
            brandingHtml: "Powered by u003ca class="icon-imgur-white" href="https://imgur.com/"u003eu003c/au003e",
            contentPolicyHtml: "User contributions licensed under u003ca href="https://creativecommons.org/licenses/by-sa/3.0/"u003ecc by-sa 3.0 with attribution requiredu003c/au003e u003ca href="https://stackoverflow.com/legal/content-policy"u003e(content policy)u003c/au003e",
            allowUrls: true
            },
            onDemand: true,
            discardSelector: ".discard-answer"
            ,immediatelyShowMarkdownHelp:true
            });


            }
            });






            Dillon Stetler is a new contributor. Be nice, and check out our Code of Conduct.










            draft saved

            draft discarded


















            StackExchange.ready(
            function () {
            StackExchange.openid.initPostLogin('.new-post-login', 'https%3a%2f%2fchemistry.stackexchange.com%2fquestions%2f114513%2fwhen-to-run-a-blank-using-icp-ms%23new-answer', 'question_page');
            }
            );

            Post as a guest















            Required, but never shown

























            1 Answer
            1






            active

            oldest

            votes








            1 Answer
            1






            active

            oldest

            votes









            active

            oldest

            votes






            active

            oldest

            votes









            2












            $begingroup$

            This terminology is specific to EPA and it is not universal, because there are so many legal issues associated with any environmental analysis. They have to be extremely careful at each and every step (it may cost someone millions because of a wrong analytical result). Hence the reason for various "blanks." The language of those methods is official and the steps are highly detailed. Hence these robust methods can be defended legally using the terminologies used in the methods.



            While preparing a calibration curve by ICP or any other spectrochemical technique, there can be only one blank, which sets the baseline reading. One would run this blank and 5-6 standards. So which blank is this? By EPA nomenclature, this is the calibration blank, which is defined by them as "Calibration Blank – A blank solution containing all of the reagents in the same concentration as those used in the analytical sample preparation. This blank is not subject to the preparation method." Pretty much standard definition.



            So what are the other plenty of blank solutions doing? They are used for quality control after the calibration to check the accuracy of the instrument, method, operator etc. One can test them right after performing the calibration process. See how specific the directions are:



            a) Laboratory Reagent Blank (LRB) – An aliquot of ASTM Type I water that is treated exactly as a sample including exposure to all labware, equipment, solvents, reagents and internal standards that are used with other samples. The LRB is used to determine if method analytes or other interferences are present in the laboratory environment, the reagents or apparatus.



            b) The rinse blank, as the name indicates for rinsing the lines. You should discuss how complex the sample introduction system is in ICPs. >90% sample is wasted and a small fraction goes to the plasma.



            EPA defines it as well. The rinse blank should flush the system between solution changes for blanks, standards, and samples. Allow sufficient rinse time (~ 1 min) to remove traces of the previous sample. Solutions should aspirate for at least 30 seconds prior to the acquisition of data to establish equilibrium



            Reference: this detailed report with terminologies



            (ICP-MS) with - EPA: https://www3.epa.gov/ttnamti1/files/ambient/pb/EQL-0512-202.pdf






            share|improve this answer









            $endgroup$


















              2












              $begingroup$

              This terminology is specific to EPA and it is not universal, because there are so many legal issues associated with any environmental analysis. They have to be extremely careful at each and every step (it may cost someone millions because of a wrong analytical result). Hence the reason for various "blanks." The language of those methods is official and the steps are highly detailed. Hence these robust methods can be defended legally using the terminologies used in the methods.



              While preparing a calibration curve by ICP or any other spectrochemical technique, there can be only one blank, which sets the baseline reading. One would run this blank and 5-6 standards. So which blank is this? By EPA nomenclature, this is the calibration blank, which is defined by them as "Calibration Blank – A blank solution containing all of the reagents in the same concentration as those used in the analytical sample preparation. This blank is not subject to the preparation method." Pretty much standard definition.



              So what are the other plenty of blank solutions doing? They are used for quality control after the calibration to check the accuracy of the instrument, method, operator etc. One can test them right after performing the calibration process. See how specific the directions are:



              a) Laboratory Reagent Blank (LRB) – An aliquot of ASTM Type I water that is treated exactly as a sample including exposure to all labware, equipment, solvents, reagents and internal standards that are used with other samples. The LRB is used to determine if method analytes or other interferences are present in the laboratory environment, the reagents or apparatus.



              b) The rinse blank, as the name indicates for rinsing the lines. You should discuss how complex the sample introduction system is in ICPs. >90% sample is wasted and a small fraction goes to the plasma.



              EPA defines it as well. The rinse blank should flush the system between solution changes for blanks, standards, and samples. Allow sufficient rinse time (~ 1 min) to remove traces of the previous sample. Solutions should aspirate for at least 30 seconds prior to the acquisition of data to establish equilibrium



              Reference: this detailed report with terminologies



              (ICP-MS) with - EPA: https://www3.epa.gov/ttnamti1/files/ambient/pb/EQL-0512-202.pdf






              share|improve this answer









              $endgroup$
















                2












                2








                2





                $begingroup$

                This terminology is specific to EPA and it is not universal, because there are so many legal issues associated with any environmental analysis. They have to be extremely careful at each and every step (it may cost someone millions because of a wrong analytical result). Hence the reason for various "blanks." The language of those methods is official and the steps are highly detailed. Hence these robust methods can be defended legally using the terminologies used in the methods.



                While preparing a calibration curve by ICP or any other spectrochemical technique, there can be only one blank, which sets the baseline reading. One would run this blank and 5-6 standards. So which blank is this? By EPA nomenclature, this is the calibration blank, which is defined by them as "Calibration Blank – A blank solution containing all of the reagents in the same concentration as those used in the analytical sample preparation. This blank is not subject to the preparation method." Pretty much standard definition.



                So what are the other plenty of blank solutions doing? They are used for quality control after the calibration to check the accuracy of the instrument, method, operator etc. One can test them right after performing the calibration process. See how specific the directions are:



                a) Laboratory Reagent Blank (LRB) – An aliquot of ASTM Type I water that is treated exactly as a sample including exposure to all labware, equipment, solvents, reagents and internal standards that are used with other samples. The LRB is used to determine if method analytes or other interferences are present in the laboratory environment, the reagents or apparatus.



                b) The rinse blank, as the name indicates for rinsing the lines. You should discuss how complex the sample introduction system is in ICPs. >90% sample is wasted and a small fraction goes to the plasma.



                EPA defines it as well. The rinse blank should flush the system between solution changes for blanks, standards, and samples. Allow sufficient rinse time (~ 1 min) to remove traces of the previous sample. Solutions should aspirate for at least 30 seconds prior to the acquisition of data to establish equilibrium



                Reference: this detailed report with terminologies



                (ICP-MS) with - EPA: https://www3.epa.gov/ttnamti1/files/ambient/pb/EQL-0512-202.pdf






                share|improve this answer









                $endgroup$



                This terminology is specific to EPA and it is not universal, because there are so many legal issues associated with any environmental analysis. They have to be extremely careful at each and every step (it may cost someone millions because of a wrong analytical result). Hence the reason for various "blanks." The language of those methods is official and the steps are highly detailed. Hence these robust methods can be defended legally using the terminologies used in the methods.



                While preparing a calibration curve by ICP or any other spectrochemical technique, there can be only one blank, which sets the baseline reading. One would run this blank and 5-6 standards. So which blank is this? By EPA nomenclature, this is the calibration blank, which is defined by them as "Calibration Blank – A blank solution containing all of the reagents in the same concentration as those used in the analytical sample preparation. This blank is not subject to the preparation method." Pretty much standard definition.



                So what are the other plenty of blank solutions doing? They are used for quality control after the calibration to check the accuracy of the instrument, method, operator etc. One can test them right after performing the calibration process. See how specific the directions are:



                a) Laboratory Reagent Blank (LRB) – An aliquot of ASTM Type I water that is treated exactly as a sample including exposure to all labware, equipment, solvents, reagents and internal standards that are used with other samples. The LRB is used to determine if method analytes or other interferences are present in the laboratory environment, the reagents or apparatus.



                b) The rinse blank, as the name indicates for rinsing the lines. You should discuss how complex the sample introduction system is in ICPs. >90% sample is wasted and a small fraction goes to the plasma.



                EPA defines it as well. The rinse blank should flush the system between solution changes for blanks, standards, and samples. Allow sufficient rinse time (~ 1 min) to remove traces of the previous sample. Solutions should aspirate for at least 30 seconds prior to the acquisition of data to establish equilibrium



                Reference: this detailed report with terminologies



                (ICP-MS) with - EPA: https://www3.epa.gov/ttnamti1/files/ambient/pb/EQL-0512-202.pdf







                share|improve this answer












                share|improve this answer



                share|improve this answer










                answered 1 hour ago









                M. FarooqM. Farooq

                2,125111




                2,125111






















                    Dillon Stetler is a new contributor. Be nice, and check out our Code of Conduct.










                    draft saved

                    draft discarded


















                    Dillon Stetler is a new contributor. Be nice, and check out our Code of Conduct.













                    Dillon Stetler is a new contributor. Be nice, and check out our Code of Conduct.












                    Dillon Stetler is a new contributor. Be nice, and check out our Code of Conduct.
















                    Thanks for contributing an answer to Chemistry Stack Exchange!


                    • Please be sure to answer the question. Provide details and share your research!

                    But avoid



                    • Asking for help, clarification, or responding to other answers.

                    • Making statements based on opinion; back them up with references or personal experience.


                    Use MathJax to format equations. MathJax reference.


                    To learn more, see our tips on writing great answers.




                    draft saved


                    draft discarded














                    StackExchange.ready(
                    function () {
                    StackExchange.openid.initPostLogin('.new-post-login', 'https%3a%2f%2fchemistry.stackexchange.com%2fquestions%2f114513%2fwhen-to-run-a-blank-using-icp-ms%23new-answer', 'question_page');
                    }
                    );

                    Post as a guest















                    Required, but never shown





















































                    Required, but never shown














                    Required, but never shown












                    Required, but never shown







                    Required, but never shown

































                    Required, but never shown














                    Required, but never shown












                    Required, but never shown







                    Required, but never shown







                    Popular posts from this blog

                    Erzsébet Schaár

                    Ponta tanko

                    Tantalo (mitologio)